Back
|
VFD Cable
High Performance Wind Turbine Tray Cable
PRIMARY: (See TABLE I)
Bare Copper
Polyester Elastomer Insulation
Color Code:
1-3. Black with White Printed Numbers 4. Green/Yellow
OVERALL CABLE:
Primaries Required: 4
FR-Fibrillated Polypropylene Filler
Aluminum (Out)/Polyester Tape, 25% Overlap
JACKET:
Separator Tape - Required
C&M Duralon™ (See TABLE 1) Wall Thickness
Final Diameter (See TABLE I)
Color: Black
Print Legend (Green Ink): GreenLINX™ E329622xx AWG 4/C (UL) TYPE WTTC 1000V 90°C FT4 OR TC-ER 600V 90°C FT4 OR c(UL) CIC 90°C DRY FT4 OR AWM 20626 --- PREMIUM CONTINOUS FLEX RoHS
Note: xx = AWG TC-ER is approved for all AWG sizes except 2AWG & 4AWG |
INDUSTRY STANDARD REQUIREMENTS:
RoHS Compliant per European Union Directive 2002/95/EC
SAFETY CERTIFICATIONS: UL Listing: TC-ER / WTTC 600V 90°C FT4, c(UL) CIC 90°C DRY FT4UL AWM: 20626 90°C 600V
MECHANICAL REQUIREMENTS:
Continuous Flex / Surge Tested  |
| | PRIMARY | JACKET |
| C&M Part # | AWG & Standing | PVC Wall | OD | Wall | Nom OD |
99910 |
2 (7x7x34/34) | .035" | .410" | .085" | 1.192" ± .050" |
99911 |
4 (7x3x50/34) | .035" | .325" | .085" | .987" ± .035" |
99912 |
6 (19x35/34) | .025" | .265" | .065" | .802" ± .030" |
99913 |
8 (7x59/34) | .025" | .217" | .065" | .686" ± .020" |
99914 |
10 (7x37/34) | .020" | .172" | .065" | .577" ± .020" |
99915 |
12 (7x24/34) | .015" | .132" | .050" | .451" ± .015" |
99916 |
14 (105/34) | .015" | .102" | .050" | .372" ± .012" |
99917 |
16 (65/34) | .015" | .089" | .050" | .341" ± .012" |
♦ Tested to 20 million cycles
♦ Note: When ordering the C&M Product, use the individual part number.
|
|